Yokogawa UT100 Series
The UT150 Temperature Controller (1/16 DIN size) is a compact, versatile, general-purpose temperature controller. The UT150 has a dynamic auto tune and the “SUPER” overshoot suppress function as standard function. The heating/cooling control, retransmission output, timer function and communication function are available as optional features.
-Small, space-saving 1/16 DIN package, 48 (W) x 48 (H) x 100 (D) (mm)
-Large 4-digit LED display
-IP65 splash-proof and dust-proof designed front panel
-Universal input for Thermocouple, RTD and DC mV/V signals
-Optional heating/cooling control capability
-Optional retransmission output of measured value (PV)
-Optional timer function
-Optional heater burnout alarm and two alarm output relays
-Standard universal power supply (100 V to 240 V AC) and optional 24 V AC/DC power supply
-Optional RS485 communication function, MODBUS, PC-Link & Ladder protocols are supported
-RoHS Compliant
Models and Suffix Codes
Model |
Suffix code |
Description |
|||
UT150
UT152 UT155 |
Temperature controller |
||||
Control output for standard- type (or for heating) | –R
–V –A |
Relay output (time-proportional PID or on/off control)
Voltage pulse output (time-proportional PID) 4 to 20mA output (continuous PID) (Note1) |
|||
Control output for cooling |
N
R
V
A |
No cooling output (standard type)
Relay output (time-proportional PID or on/off control) Voltage pulse output (time-proportional PID) 4 to 20mA output (continuous PID) |
|||
Option |
/AL
/HBA
/EX
/RET /RS /V24 |
Alarm outputs (2 points) (Note2) Heater disconnection alarm
(includes optional /AL function) (Note1) (Note2) (Note3) SP1/SP2 switching, starting of timer, and RUN/STOP switching by external contacts (Note4) PV retransmission output in 4 to 20mA (Note3) Communication function (Note4) (Note5) Power Supply 24V DC / 24V AC |
Note1: /HBA option cannot be specifed when 4 to 20 mA output (heating-side) is specifed.
Note2: /AL option cannot be specifed when /HBA option is specifed.
/HBA option already includes the /AL option.
Note3: /HBA option and /RET option cannot be specifed at the same time.
Note4: /EX option and /RS option cannot be specifed at the same time.(model UT150 only)
Note5: /EX option includes contact input 1 (for switching between the SP1 and SP2 target setpoints using external contacts) and contact input 2 (for enabling the timer).
Note6: When specifying the /RS option, be sure to order the required number of copies of Communication Functions Instruction Manual separeately. You will not be supplied and instruction manual just because you order for the /RS option.