Omron Proximity Sensor E2K-L Series
Features:
Bypass pipe mounting type
Applicable to φ8 ~ 11mm, φ12 ~ 26mm large diameter
Amplifier built-in, space-saving installation
species:
Ontology
Detection method for diameter shape output form / action
mode model
Capacitance mode φ8 ~ 11mm
475_lu_1_1
NPN open collector output NO E2K-L13MC1 2M
Φ12 ~ 26mm
475_lu_1_2
E2K-L26MC1 2M
Rating / Performance:
Item Model E2K-L13MC1 E2K-L26MC1
Applicable pipe material Nonmetal
Size Outer diameter φ8 ~ 11mm φ12 ~ 26mm
Wall thickness 1mm below 1.5mm or less
Can detect object liquid *
Repeat distance ± 0.2mm or less
Should be due to pipe size, solution and change
The reference value of 0.6 ~ 5mm 0.3 ~ 3mm
Power supply voltage (using voltage) DC12 ~ 24V Ripple 10%
or less (DC10.8 ~ 30V)
Current consumption below 12mA
Control output switch capacity of 100mA or less
Residual voltage 1V or less (load current: 100mA, wire
length: 2m)
Check the level mark position
Indicator light detection display (orange)
Ambient temperature range Use: 0 ~ +55 ℃, save: -10 ~ +65
℃ (no icing, condensation)
Ambient temperature range When used, save: 25 ~ 85% RH (no
condensation)
Temperature of 0 ~ + 55 ℃ temperature range +23 ℃, the
detection level of ± 4mm (pure water and 20% saline)
(E2K-L13MC1 pipe diameter φ8 pure water is ± 6mm)
Voltage of the rated power supply voltage within ± 10% of
the rated power supply voltage when the detection level of ± 0.5mm
Insulation resistance 50MΩ or more (DC500V megger) The
charging unit is integral with the housin
Withstand voltage AC500V 50 / 60Hz 1min charging part
between the whole and the shell
Vibration (durable) 10 ~ 55Hz up and down amplitude 1.5mm X, Y, Z direction 2h
Impact (durable) 500m / s2 X, Y, Z direction 3 times
Protection structure IEC standard
Connection type wire lead type (standard wire length 2m)
Quality (after packaging) about 70g
Material shell, cover heat ABS
Wire clip NBR
Accessories with two straps, anti-slip tube 4, the use of manual
* In the following cases, there is a problem that can not be
measured, and the test performance must be confirmed on the
device to be used.
(1) When the relative dielectric constant or the
conductivity of the liquid is low, the electrostatic
capacity type is used, and the liquid level may not be detected.
(2) In the case where the liquid capacity is small or the
corresponding capacity change of the liquid level changes is
small due to the small diameter and the wall thickness of the pipe size
(3) the inner wall of the pipeline has a high viscosity
liquid film and a large number of foam residues, or pipe
wall attached to the accumulation of dirt and so on