KEYENCE Proximity Sensors EX-500 series EX-501
Model | EX-501 | |||
Type | Controller | |||
Shape | M8, Threaded, Non-shielded | |||
Measuring range | 0 to 1mm 0.04″ | |||
Analog output | Output voltage | 0 to 5 V (Output impedance: 100 Ω)*1 | ||
Impedance | 100 Ω*2 | |||
Output current | 4 to 20 mA (Applicable load: 0 to 350 Ω)*1 | |||
Resolution | 0.03% of F.S. (RESPONSE = 3, 4)*2 | |||
Linearity | ±0.3% of F.S. (RESPONSE = 2, 3, 4)*1 | |||
Response time (Response mode) |
0.1 ms (RESPONSE = 1), 1 ms (RESPONSE = 2), 10 ms (RESPONSE = 3), 100 ms (RESPONSE = 4)*2 | |||
Disconnection alarm output (N.C.) | NPN: 100 mA max. (40 V), Residual voltage: 1 V max.*3 | |||
Functions | Auto-zero function/Auto-span function, Response time selector function/ Preset metal characteristic memory function, Cable length selector function/Interference suppression function |
|||
Temperature characteristics | 0.04% of F.S./°C*2 | |||
Temperature fluctuation |
Sensor head | 0.03% of F.S./°C*4*2 | ||
Temperature characteristics | Amplifier unit | 0.04% of F.S./°C*2 | ||
Rating | Power voltage | 12 to 24 VDC ±10% | ||
Current consumption. | 220 mA max. | |||
Environmental resistance | Enclosure rating | IP67 | ||
Operating temperature range | 0 to 50°C 32 to 122°F | |||
Operating ambient humidity | 35 to 85% RH (No condensation) | |||
Vibration | 10 to 55 Hz, double amplitude: 1.5 mm 0.06″, 2 hours in each of X, Y, and Z directions | |||
Weight | Approx 360 g | |||